Changes
On May 22, 2023 at 12:22:17 PM UTC,
-
No fields were updated. See the metadata diff for more details.
| f | 1 | { | f | 1 | { |
| 2 | "author": "", | 2 | "author": "", | ||
| 3 | "author_email": null, | 3 | "author_email": null, | ||
| 4 | "creator_user_id": "fa193346-5c2f-457e-8f46-c1990af53f97", | 4 | "creator_user_id": "fa193346-5c2f-457e-8f46-c1990af53f97", | ||
| 5 | "id": "51ce7625-7877-495c-bac2-0e8c650cccc7", | 5 | "id": "51ce7625-7877-495c-bac2-0e8c650cccc7", | ||
| 6 | "license_id": "iaea", | 6 | "license_id": "iaea", | ||
| 7 | "maintainer": "", | 7 | "maintainer": "", | ||
| 8 | "maintainer_email": "", | 8 | "maintainer_email": "", | ||
| 9 | "metadata_created": "2023-05-22T12:22:04.785786", | 9 | "metadata_created": "2023-05-22T12:22:04.785786", | ||
| t | 10 | "metadata_modified": "2023-05-22T12:22:04.785804", | t | 10 | "metadata_modified": "2023-05-22T12:22:16.664232", |
| 11 | "name": "halden-reactor-test-ifa-650-9-pwr1", | 11 | "name": "halden-reactor-test-ifa-650-9-pwr1", | ||
| 12 | "notes": "The Halden Reactor test series IFA-650 was part of the | 12 | "notes": "The Halden Reactor test series IFA-650 was part of the | ||
| 13 | joint international programme of the Halden Reactor Project. These | 13 | joint international programme of the Halden Reactor Project. These | ||
| 14 | tests addressed the LOCA performance of high burnup fuel irradiated in | 14 | tests addressed the LOCA performance of high burnup fuel irradiated in | ||
| 15 | commercial nuclear power plants. \r\nIFA-650.9 (PWR fuel): | 15 | commercial nuclear power plants. \r\nIFA-650.9 (PWR fuel): | ||
| 16 | considerable ballooning, fuel fragmentation and relocation, when | 16 | considerable ballooning, fuel fragmentation and relocation, when | ||
| 17 | subjected to LOCA were indicated.\r\nThe fuel was provided by | 17 | subjected to LOCA were indicated.\r\nThe fuel was provided by | ||
| 18 | Framatome ANP and had been irradiated in the Swiss NPP G\u00f6sgen to | 18 | Framatome ANP and had been irradiated in the Swiss NPP G\u00f6sgen to | ||
| 19 | 89.9 MWd/kgU. The rod power was set to 25 kW/m to achieve a target | 19 | 89.9 MWd/kgU. The rod power was set to 25 kW/m to achieve a target | ||
| 20 | peak cladding temperature of 1100\u00b0C. Due to fuel relocation, the | 20 | peak cladding temperature of 1100\u00b0C. Due to fuel relocation, the | ||
| 21 | temperature measured with the lower cladding thermocouple approached | 21 | temperature measured with the lower cladding thermocouple approached | ||
| 22 | 1200\u00b0C, and the test was terminated to avoid even higher | 22 | 1200\u00b0C, and the test was terminated to avoid even higher | ||
| 23 | temperatures. Cladding failure occurred at about 800\u00b0C, which was | 23 | temperatures. Cladding failure occurred at about 800\u00b0C, which was | ||
| 24 | 130 s after the start of blow-down.\r\nA special feature of this | 24 | 130 s after the start of blow-down.\r\nA special feature of this | ||
| 25 | experiment is the strong fuel fragmentation, relocation and | 25 | experiment is the strong fuel fragmentation, relocation and | ||
| 26 | dispersal.", | 26 | dispersal.", | ||
| 27 | "owner_org": "dd7599ef-0a83-4e45-bbed-e3dcfcdff6b1", | 27 | "owner_org": "dd7599ef-0a83-4e45-bbed-e3dcfcdff6b1", | ||
| 28 | "private": false, | 28 | "private": false, | ||
| 29 | "revision_id": "1e3c2632-7d10-4dce-83cf-00c76a93cb4c", | 29 | "revision_id": "1e3c2632-7d10-4dce-83cf-00c76a93cb4c", | ||
| 30 | "state": "draft", | 30 | "state": "draft", | ||
| 31 | "title": "Halden Reactor Test IFA-650.9 (PWR)", | 31 | "title": "Halden Reactor Test IFA-650.9 (PWR)", | ||