Changes
On May 22, 2023 at 12:22:52 PM UTC, Clinton Tak:
-
No fields were updated. See the metadata diff for more details.
f | 1 | { | f | 1 | { |
2 | "author": "", | 2 | "author": "", | ||
3 | "author_email": null, | 3 | "author_email": null, | ||
4 | "creator_user_id": "fa193346-5c2f-457e-8f46-c1990af53f97", | 4 | "creator_user_id": "fa193346-5c2f-457e-8f46-c1990af53f97", | ||
5 | "id": "51ce7625-7877-495c-bac2-0e8c650cccc7", | 5 | "id": "51ce7625-7877-495c-bac2-0e8c650cccc7", | ||
6 | "license_id": "iaea", | 6 | "license_id": "iaea", | ||
7 | "maintainer": "", | 7 | "maintainer": "", | ||
8 | "maintainer_email": "", | 8 | "maintainer_email": "", | ||
9 | "metadata_created": "2023-05-22T12:22:04.785786", | 9 | "metadata_created": "2023-05-22T12:22:04.785786", | ||
t | 10 | "metadata_modified": "2023-05-22T12:22:43.448737", | t | 10 | "metadata_modified": "2023-05-22T12:22:52.573244", |
11 | "name": "halden-reactor-test-ifa-650-9-pwr1", | 11 | "name": "halden-reactor-test-ifa-650-9-pwr1", | ||
12 | "notes": "The Halden Reactor test series IFA-650 was part of the | 12 | "notes": "The Halden Reactor test series IFA-650 was part of the | ||
13 | joint international programme of the Halden Reactor Project. These | 13 | joint international programme of the Halden Reactor Project. These | ||
14 | tests addressed the LOCA performance of high burnup fuel irradiated in | 14 | tests addressed the LOCA performance of high burnup fuel irradiated in | ||
15 | commercial nuclear power plants. \r\nIFA-650.9 (PWR fuel): | 15 | commercial nuclear power plants. \r\nIFA-650.9 (PWR fuel): | ||
16 | considerable ballooning, fuel fragmentation and relocation, when | 16 | considerable ballooning, fuel fragmentation and relocation, when | ||
17 | subjected to LOCA were indicated.\r\nThe fuel was provided by | 17 | subjected to LOCA were indicated.\r\nThe fuel was provided by | ||
18 | Framatome ANP and had been irradiated in the Swiss NPP G\u00f6sgen to | 18 | Framatome ANP and had been irradiated in the Swiss NPP G\u00f6sgen to | ||
19 | 89.9 MWd/kgU. The rod power was set to 25 kW/m to achieve a target | 19 | 89.9 MWd/kgU. The rod power was set to 25 kW/m to achieve a target | ||
20 | peak cladding temperature of 1100\u00b0C. Due to fuel relocation, the | 20 | peak cladding temperature of 1100\u00b0C. Due to fuel relocation, the | ||
21 | temperature measured with the lower cladding thermocouple approached | 21 | temperature measured with the lower cladding thermocouple approached | ||
22 | 1200\u00b0C, and the test was terminated to avoid even higher | 22 | 1200\u00b0C, and the test was terminated to avoid even higher | ||
23 | temperatures. Cladding failure occurred at about 800\u00b0C, which was | 23 | temperatures. Cladding failure occurred at about 800\u00b0C, which was | ||
24 | 130 s after the start of blow-down.\r\nA special feature of this | 24 | 130 s after the start of blow-down.\r\nA special feature of this | ||
25 | experiment is the strong fuel fragmentation, relocation and | 25 | experiment is the strong fuel fragmentation, relocation and | ||
26 | dispersal.", | 26 | dispersal.", | ||
27 | "owner_org": "dd7599ef-0a83-4e45-bbed-e3dcfcdff6b1", | 27 | "owner_org": "dd7599ef-0a83-4e45-bbed-e3dcfcdff6b1", | ||
28 | "private": false, | 28 | "private": false, | ||
29 | "revision_id": "1e3c2632-7d10-4dce-83cf-00c76a93cb4c", | 29 | "revision_id": "1e3c2632-7d10-4dce-83cf-00c76a93cb4c", | ||
30 | "state": "draft", | 30 | "state": "draft", | ||
31 | "title": "Halden Reactor Test IFA-650.9 (PWR)", | 31 | "title": "Halden Reactor Test IFA-650.9 (PWR)", | ||
32 | "type": "dataset", | 32 | "type": "dataset", | ||
33 | "url": "", | 33 | "url": "", | ||
34 | "version": "" | 34 | "version": "" | ||
35 | } | 35 | } |